SDH Sentinel Dual (Low Power)

£0.00

Riello UPS SDH 700 - 3000 VA UPS

SDH 1000 SDH 1500 SDH 2200 SDH 2200 ER SDH 3000 SDH 3000 ER

Quantity:
Add To Cart

Riello UPS SDH 700 - 3000 VA UPS

SDH 1000 SDH 1500 SDH 2200 SDH 2200 ER SDH 3000 SDH 3000 ER

 
Overview.png

Ashdale are delighted to present our range of Riello SDH - Sentinel Dual Uninterruptible Power Supplies to the Northern Ireland market. In Riello we represent a Global UPS company with full local support. We are an officially recognised sales and service partner for Riello UPS. Many systems and accessories in stock in Belfast for immediate dispatch or collection.

Power Range: 700 - 3000 VA 1 : 1

Highlights

  • Rack Mounting

  • True On line

  • Simple plug and play installation 

  • Add additional battery packs for extended runtimes

  • Load-controlled fan speed minimises noise (< 40 dBA) 

  • Reduce power consumption with ECO and Smart Active modes 

  • 5-year warranty provides additional peace of mind 

High efficiency and density.

Sentinel Dual is the new range of high density double conversion ON LINE UPS suitable for powering a wide range of devices such as servers, storage systems, VoIP telephony equipment, network and medical systems as well as industrial applications.

Riello UPS Sales and Service Agent
InDetail_wf.png
 

It is also ideal for powering and protecting Blade Server systems with high input power factor. At only 2U, Sentinel Dual is ideal for 19” rack cabinet installations. Sentinel Dual has a practical, modern design and includes several performance advantages over traditional ON LINE UPS. All developed by the Riello UPS research and development team. The newly-designed inverter is one of the best energy conversion systems on the market, with a 0.9 output power factor and 92% operating efficiency in ON LINE Mode. For business continuity applications requiring long battery runtimes, battery autonomy can be extended up to several hours using ER models fitted with more powerful battery chargers. With energy savings in mind, Sentinel Dual is also fitted with a shut-off button to reduce energy consumption to zero during prolonged periods of inactivity.

  • 

    SIMPLIFIED INSTALLATION

  • Sentinel Dual can be installed as a tower or in 19” rack cabinets, by simply pulling out and rotating the display panel;

  • Low noise (<40 dBA): can be installed in any environment thanks to its high frequency switching inverter and PWM load-dependent digitally controlled fan;

  • Operation guaranteed up to 40 °C (the components are designed for high temperatures and are thus subject to less stress at normal temperatures);

  • On Sentinel Dual models, the output sockets can be programmed to disconnect less critical loads during blackouts (EnergyShare function).

REDUCED MANAGEMENT COSTS

The UPS is highly flexible and easy to configure. Programmable functions can be set via software or manually via the front display panel. Sentinel Dual can be configured in the following operating modes:

  • ON LINE: maximum load protection and output voltage waveform quality;

  • ECO Mode: to increase efficiency (up to to 98%); allows you to select LINE INTERACTIVE technology;

  • SMART ACTIVE: the UPS automatically decides the operating mode based on the mains power quality;

  • STANDBY OFF: the UPS can be selected to function only when the mains power supply fails (emergency only mode);

  • Frequency Converter: operation (50 or 60 Hz).

ADVANCED COMMUNICATION

Sentinel Dual offers maximum flexibility for integration with all types of communication systems.

  • Multi-platform communication for all operating systems and network environments: PowerShield³ supervision and shutdown software for Windows operating systems 10, 8, 7, Hyper-V, 2019, 2016, 2012, and previous versions, Mac OS X, Linux, VMWare ESXi, Citrix XenServer and other Unix operating systems;

  • UPS Tools configuration and customisation software supplied as standard;

  • RS232 serial port and opto-isolated contacts;

  • USB port;

  • Slot for communications boards such as Modbus/Jbus, TCP/IP-SNMP and relay contacts.

HIGH OUTPUT VOLTAGE QUALITY

  • Even with non-linear loads (IT loads with a crest factor of up to 3:1);

  • High short circuit current on bypass;

  • High overload capacity: 150% by inverter (even with mains failure);

  • Filtered, stabilised and reliable voltage (ON LINE double conversion technology (VFI compliant with EN62040-3) with filters for the suppression of atmospheric disturbances;

  • Power factor correction: UPS input power factor close to 1 and sinusoidal current uptake.

HIGH LEVELS OF BATTERY RELIABILITY

  • Automatic and manual battery test;

  • Batteries are user replaceable without switching off equipment and without interruption to the load (Hot Swap);

  • Unlimited extendible runtime using matching battery cabinets.

OTHER FEATURES

  • Output voltage can be selected via software (220/230/240 V);

  • Auto-restart when mains power is restored (programmable via software);

  • STANDBY ON bypass: when the machine is switched off, it automatically goes into bypass and battery charge mode;

  • Minimum load switch-off;

  • Battery discharge warning;

  • Start up delay;

  • Total microprocessor control;

  • Automatic bypass without interruption;

  • Status, measurements and alarms available on standard backlit display;

  • UPS firmware updating via PC;

  • Input protection via resettable thermal switch (versions up to 1500 VA);

  • Back-feed protection standard: to prevent energy from being fed back to the network;

WhyAshdale.png
 
IMG_9793 (2).JPG

We are a one stop shop for a power protection solution that will give you or your client total peace of mind.

  • The know-how and experience to specify the appropriate solution

  • Handle Logistics of Supply & Installation.

  • Commission the final system

  • Decommission & removal of existing systems

  • Provide 24/365 Contracted Support

  • Supply spare parts and batteries

  • Our technical team are OEM trained and certified so you can trust us to provide the very best support in sales and service.

If you have an application, please get touch we love solving problems !

Models.png
 

SDH 1000 SDH 1500 SDH 2200 SDH 2200 ER SDH 3000 SDH 3000 ER

Battery Packs

BB SDH 36V A3 BB SDH 36V M1 BB SDH 36V B1 BB SDH 72V A3 BB SDH 72V M1 BB SDH 72V B1 BB SER 72V A5

Accessories

RACK GUIDE KIT 1-3KVA RACK GUIDE KIT 4-10KVA PowerShield3 Lite PowerShield3 Full MultiCOM 351 MultiCOM 352 MultiCOM 362 MultiCOM 372 MultiCOM 384 MULTIPASS 10A MULTIPASS 16A MULTIPASS-R 16A AS/400 kit NETMAN 204 4GB

 
Discovermore.png
 
Software

Software

Catalogue

Catalogue

Datasheet

Datasheet

 

We have experts with a wealth of knowledge ready to help you at our Belfast HQ.

Call us on 02890783000 or use the contact form and we’ll get back to you.